Skip to product information
1 of 1

AOI | Process Insights

Series 1300 Oxygen Deficiency Monitor

Series 1300 Oxygen Deficiency Monitor

Regular price $2,243.00 USD
Regular price Sale price $2,243.00 USD
Sale Sold out
Size

Our ALPHA OMEGA INSTRUMENTS™ Series 1300™ oxygen deficiency monitor is a digitally controlled instrument with a measuring range of 0-30%. Oxygen values are displayed to the nearest tenth of a percent on a high contrast front panel liquid crystal display (LCD).   The monitor is housed in a resilient polycarbonate, wall-mountable general-purpose enclosure. Standard input power to the Series 1300 is 90-264 VAC, 47-63 Hz. and 18-36 VDC powered systems are available.

Pricing for US, LATAM, and Canada Only.

Outside of US, LATAM, or Canada, please request a quote. sales.hou@process-insights.com

The eloquence of the Series 1300 is its simple operation, as well as its ease of expandability. Included are four individually adjustable Form C alarm relays, each rated at 10 amps (250 VAC). The Series 1300 can be programmed to provide a maximum of nine individual alarm events. Two scalable analog outputs (4-20 mADC and 0-20 mADC) are standard, as is RS-232 serial communications. Each Series 1300 includes an internally mounted audible alarm rated at 85 decibels (nominal) as well as visual alarm indicators. 

DOWNLOAD DATASHEET

PERFORMANCE

  • Measurement Range: 0 to 30%
  • Accuracy: ±​1% of full scale
  • Response Time: 90% of full-scale response in < 20 seconds (nominal)
  • Sensor Type: Extended life electrochemical sensor
  • Temperature Compensation: Standard
  • Operating Temperature: 50° to 104° F (10° to 40°C)
  • Humidity: 90% maximum (non-condensing).
  • Product Warranty: Three years for both sensor and electronics
  • Calibration: Calibrated at factory with certificate of calibration

ELECTRICAL

  • Display: 4 Line by 20-character LCD
  • Input Power: Universal 90 to 264 VAC, 47 to 63 Hz standard. Optional 18-36 VDC.
  • Standard Outputs: Two 0-20 mADC or 4-20 mADC, user configurable.
  • Serial Communications: RS-232 standard
  • Oxygen Alarm Relays: Four (4) SPDT form C contacts rated 10A (250 VAC) 5A (100 VDC)
  • Alarms may be cleared manually or automatically (latching), user configurable.
  • Audible Alarm: Internal audible alarm with specific alarm canceling accessible via menu

    The Enhanced Electrolyte System (EES) is a technology used our Series 1300 oxygen monitors to improve the sensor’s performance and lifespan. The EES technology utilizes a unique combination of materials in the sensor’s electrolyte solution, which provides several benefits over traditional sensors. One of the primary benefits of the EES technology is its ability to reduce the effects of harsh environments, such as high humidity and corrosive gases, on the sensor’s performance. This technology also allows for faster sensor response times and more stable readings, improving the accuracy of the oxygen measurement. In addition, the EES technology can extend the lifespan of the sensor, reducing the need for frequent replacements and maintenance

    • The Series 1300 oxygen deficiency monitor can be equipped with a local oxygen sensor and/or up-to two remote sensors.
    • The sensors featured in the Series 1300 are extended life electrochemical oxygen sensors designed with a proprietary Enhanced Electrolyte System (EES) that extends the life expectancy of the sensor to years instead of approximately 12 months typical of most “fuel cell type” sensors. 
    • The oxygen sensors in the Series 1300 are designed with open diffusers eliminating the need to use sample pumps. 
    • We back each Series 1300 oxygen sensor with a full three-year warranty. Users can expect sensor life well beyond 5 years, helping to ensure reliable and trouble-free performance.

    1300 with AC power with local sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR - WITH LOCAL SENSOR.
    Universal AC (90-264 VAC) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. 

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with local sensor, 2 remote sensors

    SERIES 1300 OXYGEN DEFICIENCY MONITOR -  WITH LOCAL SENSOR and TWO REMOTE SENSORS.
    Universal AC (90-264 VAC) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with AC power with 1 remote sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR -  WITH LOCAL SENSOR and TWO REMOTE SENSORS.
    Universal AC (90-264 VAC) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready.

    Warranty:  3 Year Warranty on Both Electronics and Sensor 

    1300 with AC power with 2 remote sensors

    SERIES 1300 OXYGEN DEFICIENCY MONITOR - WITH NO LOCAL SENSOR and TWO REMOTE SENSORS.
    Universal AC (90-264 VAC) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with local sensor, 1 remote sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR -  WITH LOCAL SENSOR and ONE REMOTE SENSOR.
    Universal AC (90-264 VAC) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. 

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with 24VDC with a local and 2 remote sensors

    SERIES 1300 OXYGEN DEFICIENCY MONITOR – WITH LOCAL SENSOR and TWO REMOTE SENSORS.
    18-36 VDC (24 VDC nominal) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. Minimum power requirement is 35 watts.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with 24VDC with local sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR – WITH LOCAL SENSOR.
    18-36 VDC (24 VDC nominal) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. Minimum power requirement is 35 watts.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with 24VDC with 1 remote sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR – WITH NO LOCAL SENSOR and ONE REMOTE SENSOR.
    18-36 VDC (24 VDC nominal) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. Minimum power requirement is 35 watts.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with 24VDC with 2 remote sensors

    SERIES 1300 OXYGEN DEFICIENCY MONITOR – WITH NO LOCAL SENSOR and TWO REMOTE SENSORS.
    18-36 VDC (24 VDC nominal) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. Minimum power requirement is 35 watts.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    1300 with 24VDC with local sensor, 1 remote sensor

    SERIES 1300 OXYGEN DEFICIENCY MONITOR – WITH LOCAL SENSOR and ONE REMOTE SENSOR.
    18-36 VDC (24 VDC nominal) with RS232, built-in datalogger, 3 sensor ready, 4 H&S ready. Minimum power requirement is 35 watts.

    Warranty:  3 Year Warranty on Both Electronics and Sensor

    View full details